RE: Problems with ATLOD after reference frame changes in AIPS

From: <Chris.Phillips_at_email.protected>
Date: Tue, 8 Dec 2009 21:29:09 +1100

Simon,

Is this using the "NRAO" version of ATLOD or the ATNF version???

Cheers
Chris
________________________________________
From: owner-vlbiobs_at_atnf.<!--nospam-->csiro.au [owner-vlbiobs_at_atnf.<!--nospam-->csiro.au] On Behalf Of Simon Ellingsen [Simon.Ellingsen_at_utas.<!--nospam-->edu.au]
Sent: Tuesday, 8 December 2009 7:51 PM
To: VLBI observers
Cc: brunthal_at_mpifr-bonn.<!--nospam-->mpg.de
Subject: Problems with ATLOD after reference frame changes in AIPS

Dear LBAers,

Most of you would have seen the emails from Eric Greisen and Craig
Walker about the changes in the AN table format and geometry
introduced into AIPS a month or two back. After running the midnight
job on my 31DEC09 distribution late last week I found that I could no
longer load LBA data into AIPS using ATLOD (it crashes as shown
below). I was able to rollback my AIPS distribution a few weeks to
prior to the reference frame changes and ATLOD now works again as
expected.

I have emailed Eric Greisen to inform him of the problem, but have not
yet had a response.

The basic message at the moment though is you can't use ATLOD with
versions of AIPS which have changed to the right-handed terrestrial
reference frame.

elling> ATLOD1: Task ATLOD (release of 31DEC09) begins
elling> ATLOD1: Using compressed uv data format.
elling> ATLOD1: Dropping all flagged visibilities.
elling> ATLOD1: Retaining autocorrelations.
elling> ATLOD1: Vis weights set to integration time in units of 15 sec
elling> ATLOD1: Averaging all pulsar bins
elling> ATLOD1:
elling> ATLOD1: Processing file: 1
elling> ATLOD1: Input polarizations: RR,LL
elling> ATLOD1:
elling> ATLOD1: Create T09149ALL .UVDATA. 1 (UV) on disk 1
cno 25
elling> ATLOD1: Recomputing UVWs for pre-20/02/1998 LBA data
elling> ATLOD1:
elling> ATLOD1: File: 1, Scan: 1
elling> ATLOD1: ZABORS: signal 10 received
elling> ATLOD1: ABORT!

Regards

Simon
--
Simon Ellingsen : Senior Lecturer Physics & Astronomy, University of
Tasmania
Currently : Humboldt Experienced Research Fellow, MPIfR, Bonn
email : Simon.Ellingsen_at_utas.<!--nospam-->edu.au
WWW   : http://fcms.its.utas.edu.au/scieng/physics/pagedetails.asp?lpersonId=681
Phone : +49 (0)228 525 392 (work)      +49 (0)1522 374 5728 (mobile)
Received on 2009-12-08 21:29:53