-Procedure for disabling DAS gain and threshold loops for pulsar observing+===== Procedure for disabling DAS gain and threshold loops for pulsar observing ​=====
 ------------------------------------------------------------------------- -------------------------------------------------------------------------
  
Line 21: Line 21:
 any pulsar signal; any pulsar signal;
  
 +<​file>​
         -the GAIN loop : a voltage-controlled amplifier ahead of the         -the GAIN loop : a voltage-controlled amplifier ahead of the
          ​sampler,​ servo'​d to maintain constant 8-bit sampled amplitude.          ​sampler,​ servo'​d to maintain constant 8-bit sampled amplitude.
Line 29: Line 30:
          the thresholds on a fixed cycle which depends on filter ​          the thresholds on a fixed cycle which depends on filter ​
          ​bandwidth. For 16MHz filters the cycle is 2^19 samples = 33ms.          ​bandwidth. For 16MHz filters the cycle is 2^19 samples = 33ms.
 +</​file>​
  
 (At Narrabri there is no GAIN loop in the DAS. In the Pre-CABB era the  (At Narrabri there is no GAIN loop in the DAS. In the Pre-CABB era the 
Line 58: Line 60:
 by Simone Magri and Mark Leach). by Simone Magri and Mark Leach).
  
-Procedure for GUI Version of control software: +=== Procedure for GUI Version of control software: ​===
-----------------------------------------------+
  
 +----------------------------------------------
 +<​file>​
  1. Wait till you're on source (or levels are stable), then adjust the  1. Wait till you're on source (or levels are stable), then adjust the
     pre-DAS attenuation to centre the "​LEVEL"​ bargraph/​slider on each      pre-DAS attenuation to centre the "​LEVEL"​ bargraph/​slider on each 
Line 128: Line 131:
     close as possible to 34.6%. These numbers are in ~0.1dB     close as possible to 34.6%. These numbers are in ~0.1dB
     steps, so if the lvl drops to say 123, remove 0.5dB to centre it.     steps, so if the lvl drops to say 123, remove 0.5dB to centre it.
 +</​file>​
  
 +=== Procedure for DOS version of control software ===
  
-Procedure for DOS version of control software 
 --------------------------------------------- ---------------------------------------------
 +<​file>​
  1. Wait till you're on source (or levels are stable), then adjust the  1. Wait till you're on source (or levels are stable), then adjust the
     pre-DAS levels/​attenuators to centre the "​LEVL"​ bargraph on each IFP.     pre-DAS levels/​attenuators to centre the "​LEVL"​ bargraph on each IFP.
Line 191: Line 195:
  8. Check, monitor and adjust sampling stats, as for GUI version above.  8. Check, monitor and adjust sampling stats, as for GUI version above.
  
 +</​file>​
  
 JER JER