lbaops:lbaapr2012:v271kholog [2012/04/24 16:27]
breid
lbaops:lbaapr2012:v271kholog [2015/12/18 16:38] (current)
Line 1: Line 1:
 +Replaced default ifd01 with the following procedure
 +
 +define ​ ifd01         ​11313031943x\\
 +ifd=4,​7,​nor,​nor\\
 +if3=4,​out,​1,​2,,,​on\\
 +lo=\\
 +lo=lo1,​8080.00,​usb,​rcp,​1.000\\
 +lo=lo2,​8080.00,​usb,​rcp,​1.000\\
 +lo=lo3,​8080.00,​usb,​rcp,​1.000\\
 +patch=\\
 +patch=lo1,​1l,​2l,​3l,​4l,​5h,​6h,​7h,​8h\\
 +enddef
 +
 +Also, output 4 was repatched from high to low. output 3 was switched by the "​1"​ in the ''​if3=4,​out,​1,​2,,,​on''​ line
 +
 +Using S/X recorder+Mark4 rack+Mark5A
  
 Recording to PKS+0021 Recording to PKS+0021
Line 7: Line 23:
  
 Observer: Stas Observer: Stas
 +
 +
 +
 +S/X receiver cryos have let go - have elevated Tsys 
 +
 +No data recored until 0348 due  to Windstows & schedule error (drudged with no recorder - LBA style)
 +
  
  