User Tools

Site Tools


lbaops:lbamar2013:v483bholog

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

lbaops:lbamar2013:v483bholog [2015/12/18 16:38] (current)
Line 1: Line 1:
 +Recording to CURT V007 A1-A7
 +
 +Agilent at 4.1 GHz
 +
 +LO set to 882 MHz (mode 1), 909 MHz (mode 2). Coherence with 453 MHz (mode 1) and 666 MHz (mode 2)
 +
 +Recording RCP/LCP
 +
 +Fringes in both modes, using vc196a and vc196b
 +
 +Polarization purity poor, cause unknown.
 +
 +Known problems: wrong LO until 20:18:30 (used mode 2 instead of mode 1). Confirmed ok with fringe check at 20:37.
  
lbaops/lbamar2013/v483bholog.txt · Last modified: 2015/12/18 16:38 (external edit)