User Tools

Site Tools


correlator:records:v252aa

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
correlator:records:v252aa [2011/09/29 20:15]
cormac created
correlator:records:v252aa [2014/11/11 18:08] (current)
Line 12: Line 12:
  
  
-[[ftp://cira.ivec.org/v252aa/v252aa.DTSUM|Brief Data Summary]]+[[http://cira.ivec.org/pipeline/v252aa/v252aa.DTSUM|Brief Data Summary]]
  
-[[ftp://cira.ivec.org/v252aa/v252aa.SCAN|Scan listing]]+[[http://cira.ivec.org/pipeline/v252aa/v252aa.SCAN|Scan listing]]
  
-[[ftp://cira.ivec.org/v252aa/v252aa_POSSM_AUTOCORR.pdf|Plots of autocorrelations]]+[[http://cira.ivec.org/pipeline/v252aa/v252aa_POSSM_AUTOCORR.pdf|Plots of autocorrelations]]
  
 **Comments:**  **Comments:** 
  
-[[ftp://cira.ivec.org/v252aa/v252aa_POSSM_UNCAL.pdf|Plots of uncalibrated amplitude and phase against frequency]]+[[http://cira.ivec.org/pipeline/v252aa/v252aa_POSSM_UNCAL.pdf|Plots of uncalibrated amplitude and phase against frequency]]
  
 **Comments:**  **Comments:** 
  
-[[ftp://cira.ivec.org/v252aa/v252aa_VPLOT_UNCAL.pdf|Plots of uncalibrated amplitude and phase against time]]+[[http://cira.ivec.org/pipeline/v252aa/v252aa_VPLOT_UNCAL.pdf|Plots of uncalibrated amplitude and phase against time]]
  
 **Comments:**  **Comments:** 
  
-[[ftp://cira.ivec.org/v252aa/v252aa_ACCOR.pdf|Amplitude corrections from ACCOR]]+[[http://cira.ivec.org/pipeline/v252aa/v252aa_ACCOR.pdf|Amplitude corrections from ACCOR]]
  
 **Comments:**  **Comments:** 
  
-[[ftp://cira.ivec.org/v252aa/v252aa_FRING_DELAY.pdf|Fringe-fit delay solutions]]+[[http://cira.ivec.org/pipeline/v252aa/v252aa_FRING_DELAY.pdf|Fringe-fit delay solutions]]
  
 **Comments:**  **Comments:** 
  
-[[ftp://cira.ivec.org/v252aa/v252aa_FRING_PHAS.pdf|Fringe-fit phase solutions]]+[[http://cira.ivec.org/pipeline/v252aa/v252aa_FRING_PHAS.pdf|Fringe-fit phase solutions]]
  
 **Comments:**  **Comments:** 
  
-[[ftp://cira.ivec.org/v252aa/v252aa_FRING_RATE.pdf|Fringe-fit rate solutions]]+[[http://cira.ivec.org/pipeline/v252aa/v252aa_FRING_RATE.pdf|Fringe-fit rate solutions]] 
 + 
 +A close inspection of the Ceduna data reveals that the phase rate is jumping approximately every minute. Ceduna data may have to be discarded, as solution intervals of significantly less than a minute will be required to recover these data for most of the experiment.
  
 **Comments:**  **Comments:** 
  
-[[ftp://cira.ivec.org/v252aa/v252aa_POSSM_CAL.pdf|Plots of Amplitude and phase against frequency with fringe-fit solutions applied]]+[[http://cira.ivec.org/pipeline/v252aa/v252aa_POSSM_CAL.pdf|Plots of Amplitude and phase against frequency with fringe-fit solutions applied]]
  
 **Comments:**  **Comments:** 
  
-[[ftp://cira.ivec.org/v252aa/v252aa_VPLOT_CAL.pdf|Plots of Amplitude and phase against time with fringe-fit solutions applied]]+[[http://cira.ivec.org/pipeline/v252aa/v252aa_VPLOT_CAL.pdf|Plots of Amplitude and phase against time with fringe-fit solutions applied]]
  
 **Comments:**  **Comments:** 
  
  
correlator/records/v252aa.txt · Last modified: 2014/11/11 18:08 (external edit)