correlator:records:v252bi [2017/07/25 13:21]
vlbi postwiki.py
correlator:records:v252bi [2017/07/25 13:24] (current)
cormac [Correlation notes]
Line 9: Line 9:
 | v252bi | V252BI.FITS |   ​| ​ 2017-06-15, 0/21:28:01 - 1/​22:​00:​59 ​ | AT CD HH HO KE MP PA TD TI WW YG  | RR LL RL LR  |  2  |  16.0  MHz  |  64  |  1.0  | | v252bi | V252BI.FITS |   ​| ​ 2017-06-15, 0/21:28:01 - 1/​22:​00:​59 ​ | AT CD HH HO KE MP PA TD TI WW YG  | RR LL RL LR  |  2  |  16.0  MHz  |  64  |  1.0  |
  
 +At: bandpass problem in subband 1/2 RCP gives reduced sensitivity. \\
 +Mp:  Stowed ~ 00:35-03:00 to fix vacuum problem on mm Rx. \\
 +Cd: Power outage required running on backup power. Most scans between 01:30-02:51 were missed. Slow slew speed thereafter results in later than expected onsource time. See the flag file. \\
 +Ti: DSS36 from 02:41 to 09:10:14. RCP in all channels from 02:​41-02:​59. Dual pol thereafter. \\ 
 +Correlator: Some sources appear to have very poor a priori positions. A spectral resolution of 0.25 MHz and integration time of 1 sec has been used to compensate for this. \\
 ===== Analysis notes: v252bi ===== ===== Analysis notes: v252bi =====
  
correlator/records/v252bi.txt · Last modified: 2017/07/25 13:24 by cormac