ATCA reference station is W104
Detailed set up in v255d_notes.txt
A priori SEFD:
CATW104 | 70 |
MOPRA | 350 |
HOB | 1240 |
CED | 550 |
PKS | 110 |
Output files:
File name | Description | DOY/UT range | Polarizations | # subbands (AIPS IFs) | Bandwidth per IF (MHz) | Spectral channels per IF/pol | Corr. int. time (s) |
---|---|---|---|---|---|---|---|
v255d_icrf1.rpf | LCP-only ICRF run at start | 055/13:20:00-14:35:20 | LL | 4 | 16 | 256 | 2 |
v255d_icrf2.rpf | LCP-only ICRF run at end | 056/00:03:30-01:00:00 | LL | 4 | 16 | 256 | 2 |
v255d_cont.rpf | Continuum pass for dual pol setup, all sources correlated (incl. maser targets) | 055/14:35:20 - 056/00:03:30 | RR, LL, RL, LR | data in IF 3+4 | 16 | 256 | 2 |
v255d_NGC6334F.rpf | 1st maser target, 6669-6671 MHz | 055/14:35:20 - 056/00:03:30 | RR, LL, RL, LR | data in IF 3+4 | 2 | 2048 | 2 |
v255d_NGC6334IN.rpf | 2nd maser target, 6669-6671 MHz | 055/14:35:20 - 056/00:03:30 | RR, LL, RL, LR | data in IF 3+4 | 2 | 2048 | 2 |
v255d_cal_fullres.rpf | 8 mins on 1934-638 and 1729-373, 6669-6671 MHz | 055/20:00:40-20:08:50 | RR, LL, RL, LR | data in IF 3+4 | 2 | 2048 | 2 |
Flag file: v255d.uvflg
Have to UVCOPy IF 4 to avoid MAXCIF error in POSSM etc.
File-1 (continuum):
Comments:
Plots of uncalibrated amplitude and phase against frequency
Comments:
Plots of uncalibrated amplitude and phase against time
Comments:
Comments:
Comments:
Comments:
Plots of Amplitude and phase against frequency with fringe-fitted solutions applied
Comments:
Plots of Amplitude and phase against time with fringe-fitted solutions applied
Comments:
File-2 (MASER-1):
Plots of amplitude and phase against frequency
Comments: OK
Plots of amplitude and phase against time
Comments: OK
File-3 (MASER-2):
Plots of uncalibrated amplitude and phase against frequency
Comments: OK
Plots of uncalibrated amplitude and phase against time
Comments: OK