User Tools

Site Tools


correlator:records:v278b

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
correlator:records:v278b [2011/09/20 14:08]
cormac
correlator:records:v278b [2014/11/11 18:08] (current)
Line 17: Line 17:
  
  
-[[ftp://​cira.ivec.org/​v278b/​v278b.DTSUM|Brief Data Summary]]+[[http://​cira.ivec.org/pipeline/​v278b/​v278b.DTSUM|Brief Data Summary]]
  
-[[ftp://​cira.ivec.org/​v278b/​v278b.SCAN|Scan listing]]+[[http://​cira.ivec.org/pipeline/​v278b/​v278b.SCAN|Scan listing]]
  
-[[ftp://​cira.ivec.org/​v278b/​v278b_POSSM_AUTOCORR.pdf|Plots of autocorrelations]]+[[http://​cira.ivec.org/pipeline/​v278b/​v278b_POSSM_AUTOCORR.pdf|Plots of autocorrelations]]
  
 **Comments:​** ​ **Comments:​** ​
  
-[[ftp://​cira.ivec.org/​v278b/​v278b_POSSM_UNCAL.pdf|Plots of uncalibrated amplitude and phase against frequency]]+[[http://​cira.ivec.org/pipeline/​v278b/​v278b_POSSM_UNCAL.pdf|Plots of uncalibrated amplitude and phase against frequency]]
  
 **Comments:​** ​ **Comments:​** ​
  
-[[ftp://​cira.ivec.org/​v278b/​v278b_VPLOT_UNCAL.pdf|Plots of uncalibrated amplitude and phase against time]]+[[http://​cira.ivec.org/pipeline/​v278b/​v278b_VPLOT_UNCAL.pdf|Plots of uncalibrated amplitude and phase against time]]
  
 **Comments:​** ​ **Comments:​** ​
  
-[[ftp://​cira.ivec.org/​v278b/​v278b_ACCOR.pdf|Amplitude corrections from ACCOR]]+[[http://​cira.ivec.org/pipeline/​v278b/​v278b_ACCOR.pdf|Amplitude corrections from ACCOR]]
  
 **Comments:​** ​ **Comments:​** ​
 Ww corrections are extremely varied. There must be a problem maintaining good sampler statistics. Ww corrections are extremely varied. There must be a problem maintaining good sampler statistics.
  
-[[ftp://​cira.ivec.org/​v278b/​v278b_FRING_DELAY.pdf|Fringe-fit delay solutions]]+[[http://​cira.ivec.org/pipeline/​v278b/​v278b_FRING_DELAY.pdf|Fringe-fit delay solutions]]
  
 **Comments:​** ​ **Comments:​** ​
 +Ww clock jump between 8 and 10 UT. Some compensation was made in the correlator
 +model, but residuals quite large in the transition period.
  
-[[ftp://​cira.ivec.org/​v278b/​v278b_FRING_PHAS.pdf|Fringe-fit phase solutions]]+[[http://​cira.ivec.org/pipeline/​v278b/​v278b_FRING_PHAS.pdf|Fringe-fit phase solutions]]
  
 **Comments:​** ​ **Comments:​** ​
  
-[[ftp://​cira.ivec.org/​v278b/​v278b_FRING_RATE.pdf|Fringe-fit rate solutions]]+[[http://​cira.ivec.org/pipeline/​v278b/​v278b_FRING_RATE.pdf|Fringe-fit rate solutions]]
  
 **Comments:​** ​ **Comments:​** ​
  
-[[ftp://​cira.ivec.org/​v278b/​v278b_POSSM_CAL.pdf|Plots of Amplitude and phase against frequency with fringe-fit solutions applied]]+[[http://​cira.ivec.org/pipeline/​v278b/​v278b_POSSM_CAL.pdf|Plots of Amplitude and phase against frequency with fringe-fit solutions applied]]
  
 **Comments:​** ​ **Comments:​** ​
  
-[[ftp://​cira.ivec.org/​v278b/​v278b_VPLOT_CAL.pdf|Plots of Amplitude and phase against time with fringe-fit solutions applied]]+[[http://​cira.ivec.org/pipeline/​v278b/​v278b_VPLOT_CAL.pdf|Plots of Amplitude and phase against time with fringe-fit solutions applied]]
  
 **Comments:​** ​ **Comments:​** ​
  
  
correlator/records/v278b.txt · Last modified: 2014/11/11 18:08 (external edit)