Output files:
File name | Description | Start date, UT range | Polarizations | # subbands (AIPS IFs) | Bandwidth per IF (MHz) | Spectral channels per IF/pol | Corr. int. time (s) |
---|---|---|---|---|---|---|---|
V316D.CAL.FITS | Continuum pass on calibrators (file size: 2.5G) | 2010-10-26, 0/12:30:01 - 0/22:59:59 | RR LL RL LR | 2 | 16.0 MHz | 256 | 2.0 |
V316D.LINE.FITS | Line pass on maser target, 6662-6664 MHz (file size: 7.9G) | 2010-10-26, 0/12:49:09 - 0/22:45:57 | RR LL RL LR | 1 | 2.0 MHz | 2048 | 2.048 |
File: V316D.CAL.FITS
Comments:
Plots of uncalibrated amplitude and phase against frequency
Comments:
Plots of uncalibrated amplitude and phase against time
Comments:
Amplitude corrections from ACCOR
Comments:
Comments:
Comments:
Comments:
Plots of Amplitude and phase against frequency with fringe-fit solutions applied
Comments:
Plots of Amplitude and phase against time with fringe-fit solutions applied
Comments:
File: V316D.LINE.FITS
Comments:
Plots of uncalibrated amplitude and phase against frequency
Comments: Maser emission visible on AT-PA baseline at ~6662.50 MHz
Plots of uncalibrated amplitude and phase against time
Comments:
Amplitude corrections from ACCOR
Comments: