Output files:
Pass | File name | Description | Start date, UT range | Antennas | Polarizations | # subbands (AIPS IFs) | Bandwidth per IF (MHz) | Spectral channels per IF/pol | Corr. int. time (s) |
---|---|---|---|---|---|---|---|---|---|
v329h | V329H.FITS | 2018-09-08, 0/03:56:01 - 1/06:58:00 | AT HO KE MP PA TD TI WA YG | RR LL RL LR | 4 | 16.0 MHz | 64 | 1.0 |
Cd: no data. Receiver failure.
Ti: DSS43. 2018y251d20h55m to 2018y252d02h55m34s. RCP only until 2018y252d02h20m00s, then dual pol.
Td: DSS36. 2018y251d18h03m to 2018y251d21h54m. RCP only.
Ke: Data before 2018y251d12h52m02s accidentally deleted before transfer. Clock is erratic resulting in large residual delays and variable rates.
WA: no fringes, reason unknown.
Plots of autocorrelations
Comments:
Plots of uncalibrated amplitude and phase against frequency
Comments:
Plots of uncalibrated amplitude and phase against time
Comments:
Plots of cross-polarization amplitude and phase against frequency (not always available)
Comments:
Amplitude corrections from ACCOR
Comments:
Fringe-fit delay solutions
Comments:
Fringe-fit phase solutions
Comments:
Fringe-fit rate solutions
Comments:
Fringe-fit SNR
Comments:
Plots of Amplitude and phase against frequency with fringe-fit solutions applied
Comments:
Plots of Amplitude and phase against time with fringe-fit solutions applied
Comments: