User Tools

Site Tools


correlator:records:v525a

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

correlator:records:v525a [2015/05/29 17:22] (current)
Line 1: Line 1:
 +====== v525a ======
 +
 +[[http://www.atnf.csiro.au/vlbi/wiki/index.php?n=LBAMar2015.V525A|Observers Wiki]]
 +
 +===== Correlation notes =====
 +
 +**Output files:**
 +^ Pass ^  File name    Description  ^  Start date, UT range  ^  Antennas  ^ Polarizations  ^  # subbands (AIPS IFs)  ^  Bandwidth per IF (MHz)  ^  Spectral channels per IF/pol  ^  Corr. int. time (s)  |
 +| v525a | V525A.CONT.FITS |    2015-03-26, 0/03:00:01 - 0/14:29:58  | AT CD HO MP PA WA  | RR LL RL LR  |  2  |  16.0  MHz  |  32  |  2.0  |
 +| v525a-line1 | V525A.LINE1.FITS |    2015-03-26, 0/03:00:01 - 0/14:29:58  | AT CD HO MP PA WA  | RR LL RL LR  |  1  |  2.0  MHz  |  2048  |  2.097152  |
 +
 +===== Analysis notes: v525a =====
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a.DTSUM|Brief Data Summary]]
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a.SCAN|Scan and Frequency listing]]
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a_POSSM_AUTOCORR.pdf|Plots of autocorrelations]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a_POSSM_UNCAL.pdf|Plots of uncalibrated amplitude and phase against frequency]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a_VPLOT_UNCAL.pdf|Plots of uncalibrated amplitude and phase against time]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a_POSSM_CPOL.pdf|Plots of cross-polarization amplitude and phase against frequency]] (not always available) \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a_ACCOR.pdf|Amplitude corrections from ACCOR]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a_FRING_DELAY.pdf|Fringe-fit delay solutions]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a_FRING_PHAS.pdf|Fringe-fit phase solutions]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a_FRING_RATE.pdf|Fringe-fit rate solutions]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a_FRING_SNR.pdf|Fringe-fit SNR]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a_POSSM_CAL.pdf|Plots of Amplitude and phase against frequency with fringe-fit solutions applied]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a_VPLOT_CAL.pdf|Plots of Amplitude and phase against time with fringe-fit solutions applied]] \\
 +**Comments:** 
 +
 +
 +===== Analysis notes: v525a-line1 =====
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1.DTSUM|Brief Data Summary]]
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1.SCAN|Scan and Frequency listing]]
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1_POSSM_AUTOCORR.pdf|Plots of autocorrelations]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1_POSSM_UNCAL.pdf|Plots of uncalibrated amplitude and phase against frequency]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1_VPLOT_UNCAL.pdf|Plots of uncalibrated amplitude and phase against time]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1_POSSM_CPOL.pdf|Plots of cross-polarization amplitude and phase against frequency]] (not always available) \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1_ACCOR.pdf|Amplitude corrections from ACCOR]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1_FRING_DELAY.pdf|Fringe-fit delay solutions]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1_FRING_PHAS.pdf|Fringe-fit phase solutions]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1_FRING_RATE.pdf|Fringe-fit rate solutions]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1_FRING_SNR.pdf|Fringe-fit SNR]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1_POSSM_CAL.pdf|Plots of Amplitude and phase against frequency with fringe-fit solutions applied]] \\
 +**Comments:** 
 +
 +[[http://cira.ivec.org/pipeline/v525a/v525a-line1_VPLOT_CAL.pdf|Plots of Amplitude and phase against time with fringe-fit solutions applied]] \\
 +**Comments:** 
 +
 +
  
correlator/records/v525a.txt · Last modified: 2015/05/29 17:22 (external edit)