correlator:records:v539a [2016/05/18 17:53]
cormac [Analysis notes: v539a-c_p1]
correlator:records:v539a [2016/05/18 18:11] (current)
cormac [Correlation notes]
Line 11: Line 11:
 | v539a-psr | V539A.PSR.1.FITS,​ V539A.PSR.2.FITS | Pulsar gated pass  |  2015-11-18, 0/11:07:02 - 0/​16:​36:​29 ​ | AT CD HO KM PA T6  | RR LL RL LR  |  4  |  8.0  MHz  |  32  |  1.0  | | v539a-psr | V539A.PSR.1.FITS,​ V539A.PSR.2.FITS | Pulsar gated pass  |  2015-11-18, 0/11:07:02 - 0/​16:​36:​29 ​ | AT CD HO KM PA T6  | RR LL RL LR  |  4  |  8.0  MHz  |  32  |  1.0  |
  
 +ATCA: A failure of the RAID used for recording the data resulted in the loss of approx 40% of the data. The missing data are distributed throughout the experiment in blocks of about 15 to 20 minutes duration.
 +
 +Km: observed with wrong sampling rate until 15:23:55. This was corrected at correlation time but this necessitated correlating the full experiment in 4x8 MHz subbands rather than the recorded 2x16 MHz bands. There should be no associated loss of data.
 +
 +T6: no fringes. Possible receiver problem.
 +
 +Tid: data accidentally deleted before correlation. ​
 ===== Analysis notes: v539a-c_p0 ===== ===== Analysis notes: v539a-c_p0 =====
  
correlator/records/v539a.txt · Last modified: 2016/05/18 18:11 by cormac