lbaops:dashints [2008/06/06 04:01]
chris.phillips
lbaops:dashints [2008/06/06 04:13]
stingay
Line 1: Line 1:
-====  DAS GUI will not start\\\ ==== +====  DAS GUI will not start\ ====
-\\\ +
-Check DAS module has loaded. E.g:\\\ +
-\\\ +
- ​cavsi1:​~>​ lsmod | grep ds\\\ +
- ​ds ​                    ​10356 ​ 4 \\\ +
-\\\ +
-If not try:\\\ +
-\\\ +
- ​su\\\ +
- /​etc/​init.d/​ds\\\ +
-\\\ +
-\\\ +
-====  DAS gives XXXX error on first config after power cycle\ ====+
 \ \
-Try a second time+Check DAS module has loaded. E.g:\ 
 +
 + ​cavsi1:​~>​ lsmod | grep ds\ 
 + ​ds ​                    ​10356 ​ 4 \ 
 +
 +If not try:\ 
 +
 + su\ 
 + /​etc/​init.d/​ds\ 
 +
 +
 +====  DAS gives communications error in purple popup window on first config after power cycle\ ==== 
 +
 +Try a second time
 +
 +====  DAS shows no flashing "​rx"​ and "​busy"​ lights on front panel of the dataset module.\ ==== 
 +
 +Bandpass on channels from that DAS will look crap.  DAS GUI will still work.\ 
 +
 +Try a reset on the module.\ 
 +
 +Try a power cycle.\ 
 +
 +Try to force the data set to load.  Chris knows how to do it. 