  • Experiment started using S/X receiver, switched to multifeed Rx @ 2245. It should have better performance. Tsys values recorded before 2245 will be out. Scaling factor to be determined.
  • recording to UTAS V002A
  • now using multifeed X band, RCP only
  • Agilent @ 14 GHz
  • 2nd LOs are 777 and 809 MHz
  • DAS profile VSOP.PRO

day 348

  • cDisko warning: recorder header time out by 1 second.
  • 07:33 stopped schedule to service receiver cryos
  • offline for 1.5 hr, recording continued throughout
  • 09:02 back on source
  • 12:30 agilent LO failed on x-band.
  • changed back to s/x receiver.
  • 2nd LO's 807 and 775 MHz.
  • changed DAS profile to VSOP_HO3.PRO
  • offline about 0.5 hr, recording continued throughout
  • 13:02 back on source
  • 16:45 Hobart finished experiment