Line 1: Line 1:
-Agilent: 4150 MHz (changed from standard 4100 MHz to avoid forbidden LO range at 560-592 MHz)+Agilent: 4150 MHz (changed from standard 4100 MHz to avoid forbidden LO range at 560-592 MHz).
  
-LO (SML01): 528 MHz+LO (SML01): 528 MHz.
  
-Coherence observed at 831.5 MHz+Coherence observed at 831.5 MHz.
  
-DAS profile: VSOP_HO.PRO+DAS profile: VSOP_HO.PRO
 + 
 +Recording to ATNFV016B.
  
 Quad hybrid tuned to 355 steps from inner limit. Tone isolation only ~10 dB. Could not achieve better than this. No obvious issues (e.g. difficulty matching amplitudes pre-tuning) present. Quad hybrid tuned to 355 steps from inner limit. Tone isolation only ~10 dB. Could not achieve better than this. No obvious issues (e.g. difficulty matching amplitudes pre-tuning) present.
 +
 +From UT 14:00-21:00 SMY02 was accidentally left on and connected to the tone port, producing a tone 837 MHz at a level of -21 dB. Unlikely to be detectable at this level?
 +