21:28 Tid started on point at 21:16:30. I used 16MHzPSR.pro which I think to disable gain control and have worked before.
21:39 Statistics - IFP1 - THRS CNTR: AUTO, THRESHOLD X-CH: 70, THRESHOLD Y-CH: 70, LEVEL CNTR: MAN, LEVEL VALUE: 496, OFFS CNTR: AUTO, OFFS VALUE: 512 IFP1 - THRS CNTR: AUTO, THRESHOLD X-CH: 70, THRESHOLD Y-CH: 70, LEVEL CNTR: MAN, LEVEL VALUE: 512, OFFS CNTR: AUTO, OFFS VALUE: 512
21:48 I am not too sure which one I need to look at but “<31> MAGN STAS:AT (0:4Lvl.Corr.34.6%, 1:3Lev.Corr.54.06%)”. Do I need to adjust this somehow? IFP1 - <31> MAGN STAS:AT (0:4Lvl.Corr.34.6%, 1:3Lev.Corr.54.06% IFP2 - <31> MAGN STAS:AT (0:4Lvl.Corr.34.6%, 1:3Lev.Corr.54.06%
21:58 set IFP1: THRS CNTR to Manual
22:15 Back to MONITOR display, IF2 appears to be good with LEVL a the centre.
22:35 Asked to ensure that sampler stats stay around 17/33 %. Cdisko shows Ch1-2 is 1-51, ch3-4 is 21-28. I am recording LCP for all input, so correlator can process ch3-4 as better data.