-Replaced default ifd01 with the following procedure 
- 
-define  ifd01         11313031943x\\ 
-ifd=4,7,nor,nor\\ 
-if3=4,out,1,2,,,on\\ 
-lo=\\ 
-lo=lo1,8080.00,usb,rcp,1.000\\ 
-lo=lo2,8080.00,usb,rcp,1.000\\ 
-lo=lo3,8080.00,usb,rcp,1.000\\ 
-patch=\\ 
-patch=lo1,1l,2l,3l,4h,5h,6h,7h,8h\\ 
-enddef 
- 
-This saves on having to re-patch the backend.  
- 
-**317 01:38UT** reset of Mark IV formatter between sources (1442-469, 1638-530). 
-Watch for clock jump! 
-** 
-317 5:40-5:47 UT** - cut power to Mark IV formatter for hard reset. during scans 0637-752 and 1424-418. back on source for 1622-253 
- 
-**317 06:07 UT**, still getting formatter errors!  
-reading as #matcn#debug: RAT 32000 ? ERROR 7 
-in log files.   
-Don't want to continuously cut power/reset as results in clock jumps. 
- 
- 
  