User Tools

Site Tools


lbaops:lbanov2012:v483aatlog

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
lbaops:lbanov2012:v483aatlog [2012/11/14 15:13]
chris.phillips
lbaops:lbanov2012:v483aatlog [2015/12/18 16:38] (current)
Line 6: Line 6:
 RECALIBRATED ARRAY BETWEEN 03:30 and 04:00 UTC - DELAYS WILL HAVE CHANGED RECALIBRATED ARRAY BETWEEN 03:30 and 04:00 UTC - DELAYS WILL HAVE CHANGED
  
 +----
 +
 +**Correlation note added 21 Jan 2013:** 
 +
 +Delays changed by -5 us at 04:00 UT. Changed again by +5 us at 09:45 (presumably due to another CABB reboot/dcal required?)
 +
 +Clock model used:
 +
 +''$CLOCK;''\\
 +''def AT;''\\
 +''                  Valid from     clock_early clock_early_epoch     rate''
 +    ''clock_early = 2012y319d00h00m00s : 39.9087145896 usec : 2012y319d01h14m00s : 0.0;''
 +    ''clock_early = 2012y319d04h00m00s : 34.7787145896 usec : 2012y319d01h14m00s : 0.0;''
 +    ''clock_early = 2012y319d09h45m00s : 40.0287145896 usec : 2012y319d01h14m00s : 0.0;''
 +''enddef;''
  
  
lbaops/lbanov2012/v483aatlog.txt · Last modified: 2015/12/18 16:38 (external edit)