User Tools

Site Tools


lbaops:lbaobservingnotes:vexcheck

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
lbaops:lbaobservingnotes:vexcheck [2017/08/07 13:14]
cormac
lbaops:lbaobservingnotes:vexcheck [2019/09/26 17:53] (current)
cormac
Line 17: Line 17:
 For ATCA For ATCA
  
-  *  Scans not too short (ATCA loses 15 sec on scan change).+  * Scans not too short (ATCA loses 15 sec on scan change).
   * Scans aligned with 5sec boundary (for ATCA)   * Scans aligned with 5sec boundary (for ATCA)
   * Encourage 1934-638 for flux calibration   * Encourage 1934-638 for flux calibration
   * Check frequency of AUTOPHASE_DETERMINE scans   * Check frequency of AUTOPHASE_DETERMINE scans
 +  * AUTOPHASE_DETERMINE scans must have at least 1 min on 200 mJy source
 +  * Do not AUTOPHASE_DETERMINE during the fringe finder section
  
 One way to check some of this is (as vlbi on ATNF unix machines): One way to check some of this is (as vlbi on ATNF unix machines):